OLEY MRT Logo
OLEY Medical — İstanbul
📞 +90 216 611 93 33
✉️ info@oleymrt.com
100% DRY UVC STERILIZATION

UVC Disinfection Cabinet for Lead Aprons & Radiation Protective Equipment

Liquid disinfectants crack internal lead plates and cause dangerous radiation leaks. OLEY MRT disinfects 4 lead aprons, 4 thyroid shields, and 4 safety glasses completely dry using 275 nm UVC LEDs—with zero material damage.

UVC Disinfection Cabinet for Lead Aprons & Radiation Protective Equipment
MEDICAL UVC STERILIZATION TECHNOLOGY • 275 nm 4+4+4 Dry UVC Sterilization
ATCC Tested
99.99%
Verified Pathogen Kill Rate
4+4+4
Aprons • Thyroid • Glasses
5–15 Min
Rapid Dry Sterilization Cycle
0% Liquid
Zero Lead Cracking / +300% Lifespan
PRODUCT OVERVIEW & OPERATING PRINCIPLE

What is the OLEY MRT UVC Disinfection Cabinet and What Problem Does It Solve?

In hospitals, radiology departments, cath labs, and operating rooms, heavy lead aprons are worn consecutively by multiple clinicians every day. Sweat, skin flora, and blood splashes turn these garments into high-risk vectors for hospital-acquired infections. However, wiping lead aprons with chemical liquids (alcohol, bleach) or folding them cracks the internal lead composite plates—creating invisible radiation leaks.

The Problem with Liquid Wiping ✕ RISK

The Problem with Liquid Wiping

Chemical liquids seep through seams, oxidize internal lead-composite sheets, and cause micro-cracks. Furthermore, sweat odors and moisture remain trapped inside folds.

The OLEY MRT 100% Dry Solution ✓ OLEY MRT 275 nm UVC

The OLEY MRT 100% Dry Solution

OLEY MRT is an automated medical sterilization cabinet. It simultaneously disinfects 4 lead aprons, 4 thyroid shields, and 4 lead glasses completely dry using 275 nm UVC LED irradiation, HEPA H13 air filtration, and active carbon odor neutralization.

01 • 4x

4 Lead Aprons

Custom hangers with 220 mm spacing—no folding, creasing, or surface friction.

02 • 4x

4 Thyroid Shields

Positioned in the upper direct UVC irradiation zone for complete neck-area hygiene.

03 • 4x

4 Lead Safety Glasses

Scratch-free dedicated rack for delicate radiation-protective eyewear and visors.

STEP-BY-STEP CLINICAL WORKFLOW

How Is OLEY MRT Used in Daily Hospital Operations?

Engineered for effortless operation by clinical staff: touch-safe, fully automated, and completed in 5 simple steps.

Authorize via RFID Card or PIN Code RFID & PIN Security
01 STEP 01 / 05

Authorize via RFID Card or PIN Code

Clinical staff tap their authorized RFID badge or enter their security PIN on the 7-inch touchscreen to unlock the electromagnetic cabinet door.

Hang Protective Equipment (4+4+4) 220 mm Hanger Spacing
02 STEP 02 / 05

Hang Protective Equipment (4+4+4)

Hang up to 4 lead aprons on the ergonomic 220 mm spaced hangers. Place 4 thyroid shields and 4 radiation safety glasses onto their dedicated racks.

Close Door & Select Cycle (5–15 Min) 7" Touch Control
03 STEP 03 / 05

Close Door & Select Cycle (5–15 Min)

Once the door closes, magnetic interlock sensors verify sealing. Select the cycle on the touchscreen: 5 Min (Quick), 10 Min (Standard), or 15 Min (Intensive OR).

360° UVC Irradiation + HEPA H13 Air Scrubbing Zero-Shadow & Odor-Free
04 STEP 04 / 05

360° UVC Irradiation + HEPA H13 Air Scrubbing

275 nm UVC LEDs and >80% reflective mirror-aluminum walls destroy microbial DNA/RNA with zero blind spots. Simultaneously, HEPA H13 and active carbon filters eliminate sweat odors and moisture.

Automated Audit Logging & Ready Signal 1500 Cycle Audit Log
05 STEP 05 / 05

Automated Audit Logging & Ready Signal

Upon completion, the cabinet powers down UVC LEDs, alerts staff via visual/audio signals, and records the cycle in its 1500-operation memory for hospital infection control audits.

🔬 OFFICIAL MICROBIOLOGICAL LABORATORY TEST REPORT • IN-VITRO

Scientifically Validated UV-C Inactivation Results (ATCC Reference Strains)

✓ Test Protocol: LAB-UVC-ATCC-275/278
✓ Method: In-Vitro 0.5 McFarland (3x Parallel Replication)
✓ Wavelength: 275–278 nm Peak UV-C

Independent in-vitro microbiological laboratory tests (0.5 McFarland standard, 10⁸ → 10³ CFU/mL suspension, 3x parallel verification) confirm the lethal efficacy of 275–278 nm UV-C irradiation against clinically critical Gram-negative bacteria, Gram-positive bacteria, and pathogenic yeast/fungi.

ATCC 25922 Nutrient Agar (37°C / 24h)

Escherichia coli

Gram-negative Bacterium

UV-C LED (0.72 mJ/cm² / 120 s) 100%
High-Dose UV-C (1.99 mJ/cm²) 100%
ATCC 12228 Nutrient Agar (37°C / 24h)

Staphylococcus epidermidis

Gram-positive Clinical Bacterium

UV-C LED (0.72 mJ/cm² / 120 s) 99.84%
High-Dose UV-C (2.66 mJ/cm²) 100%
ATCC 1029 Sabouraud Agar (30±2°C / 48h)

Candida albicans

Pathogenic Yeast / Fungus

UV-C LED (0.72 mJ/cm² / 120 s) 98.23%
High-Dose UV-C (3.32 mJ/cm²) 100%

📊 Dose-Response Table 1: 275–278 nm UV-C LED Irradiation (Low-Dose Precision Kinetics)

Time (sec) UV-C Dose (mJ/cm²) E. coli
ATCC 25922
S. epidermidis
ATCC 12228
C. albicans
ATCC 1029
0 s 0.00 0.0% 0.0% 0.0%
15 s 0.09 25.4% 22.6% 39.1%
30 s 0.18 41.7% 40.3% 51.5%
45 s 0.27 52.2% 59.4% 59.4%
60 s 0.36 71.8% 82.8% 78.7%
75 s 0.45 77.4% 95.7% 86.9%
90 s 0.54 91.9% 98.1% 96.0%
105 s 0.63 98.8% 99.5% 97.4%
120 s 0.72 100.0% 99.84% 98.23%

📈 Dose-Response Table 2: High-Dose UV-C Sterilization Curve (Up to 100% Total Eradication)

Time (sec) UV-C Dose (mJ/cm²) E. coli
ATCC 25922
S. epidermidis
ATCC 12228
C. albicans
ATCC 1029
0 s 0.00 0.0% 0.0% 0.0%
3 s 0.40 34.1% 49.7% %
6 s 0.80 54.8% 74.3% %
9 s 1.20 78.0% 83.6% %
12 s 1.59 98.1% 87.7% %
15 s 1.99 100.0% 96.6% 94.2%
20 s 2.66 100.0% 100.0% 99.6%
25 s 3.32 100.0% 100.0% 100.0%
30 s 3.98 100.0% 100.0% 100.0%

* Test Note: All values represent the arithmetic mean of triplicate standardized in-vitro laboratory trials conducted on certified ATCC reference strains without chemical additives.

6 CORE TECHNOLOGIES AT A GLANCE

Medical Engineering at the Highest Safety Standard

Large-format visual breakdown of optical, thermal, and electronic protection systems tailored for mobile & clinical presentations.

Molecular DNA/RNA Disruption 275 nm UV-C LED

Molecular DNA/RNA Disruption

Targeted 275 nm UV-C photons cleave thymine and cytosine base pairs in bacteria, viruses, and fungal spores, halting replication immediately.

360° Zero-Shadow Mirror Chamber >80% REFLECTIVITY

360° Zero-Shadow Mirror Chamber

Diamond-geometry mirror aluminum walls bounce UVC photons into every fold, seam, and buckle of suspended aprons.

Odor & Moisture Elimination HEPA H13 + ACTIVE CARBON

Odor & Moisture Elimination

1 HEPA H13 filter captures 99.97% of airborne particulates while 2 active carbon filters neutralize surgical sweat odors inside the chamber.

Active Thermal Protection (<60°C) NTC THERMAL CONTROL

Active Thermal Protection (<60°C)

High-precision NTC thermistors protect both the UVC LED chips (up to 100,000 hrs lifespan) and delicate lead-composite aprons from heat stress.

Surge & Short-Circuit Protection ELECTRICAL SAFETY

Surge & Short-Circuit Protection

Industrial constant-current driver architecture shields the system against hospital grid fluctuations and voltage spikes.

Before / After Surface Hygiene CLINICAL COMPARISON

Before / After Surface Hygiene

Complete eradication of microbial contamination across collars, inner linings, and straps without a single drop of liquid.

TECHNICAL SPECIFICATIONS & TENDER DATA

Hardware & Cabinet Parameters

Simultaneous Capacity
4 Lead Aprons + 4 Thyroid Shields + 4 Safety Glasses
Hanger Spacing
220 mm ergonomic non-contact spacing
Sterilization Technology
275 nm Deep UV-C LED (100% dry, ozone-free, mercury-free)
Inner Chamber Optics
360° Zero-Shadow Mirror Aluminum (>80% UV-C Reflectivity)
Air Filtration System
1x HEPA H13 Filter (99.97%) + 2x Active Carbon Odor Filters
Control & Interface
7" Capacitive Touchscreen (5 / 10 / 15 Min Cycles)
Access & Audit Memory
RFID Card Reader + PIN Code + 1500 Cycle Internal Log Memory
Door Safety Interlock
Magnetic sensor with <0.05 sec instant UVC power cut-off
Chassis & Mobility
Antibacterial electrostatic stainless steel body + 4 locking heavy-duty casters
OLEY MRT Production

Frequently Asked Questions (FAQ)

Does UV-C light damage the internal lead or outer fabric of lead aprons? +

No. Unlike alcohol or chlorine-based liquid disinfectants, 275 nm UV-C light does not corrode or crack internal lead-composite sheets, extending apron service life by up to 300%.

What happens if someone accidentally opens the door during a cycle? +

Dual magnetic safety interlocks detect door opening in less than 0.05 seconds (50 milliseconds) and immediately cut power to the UVC LEDs, preventing any radiation exposure.

How are sweat odors removed after long surgical procedures? +

The integrated air circulation system continuously passes chamber air through a HEPA H13 filter and dual active carbon filters, eliminating sweat odors and moisture within the 5–15 minute cycle.

OLEY MEDICAL • ISTANBUL

Contact, Demo & Tender Documentation

Request a commercial quote, official product guide, or hospital tender specifications directly from OLEY Medical.

Factory & Headquarters
Meclis Mah. Aktürk Sok. No:4/A Sancaktepe / İstanbul / Türkiye
GPS: 41°00'33.6"N 29°12'42.9"E (41.009339, 29.211915) 📍 Open Location in Google Maps
📘 Product Guide (PDF) WhatsApp