Placement (0 min)
Lead aprons, thyroid shields and radiation protective equipment are placed on the hanging system without touching each other.
Oley MRT UVC disinfection cabinet is specially developed for hygienic cleaning of lead aprons and radiation protective equipment. Its UVC LED technology provides effective disinfection without damaging equipment.
OLEY MRT combines lead apron placement, secure locking, intensive UVC irradiation and recorded release flow in one controlled cycle.
Lead aprons, thyroid shields and radiation protective equipment are placed on the hanging system without touching each other.
The door is locked by RFID or password; contact with the outside environment is completely cut off. The magnetic switch is active.
The automatic cycle is completed and the system creates a log record. Protective equipment is ready for hygienic use.
40 LEDs are activated. “Zero-shadow” irradiation and HEPA circulation begin.
OLEY MRT turns radiology equipment hygiene from a personal habit into a reliable system with hanging disinfection, traceable cycle records and a safe enclosed cabinet structure.
The UVC process helps reduce the operational burden caused by frequent chemical wiping of lead aprons, thyroid shields and radiation protective accessories.
Creates a repeatable protective equipment hygiene routine in radiology, fluoroscopy, angiography, operating rooms and interventional procedure areas.
RFID access and cycle memory help make lead apron cleaning processes more visible, standardized and reportable.
In healthcare environments, microorganisms can be transferred not only through patient contact but also through shared surfaces, hands, gloves and reusable equipment. Lead aprons and radiation protective equipment should be included in a regular hygiene protocol because they are frequently handled.
Hospital-acquired infections can spread through a chain of transmission between patients, healthcare workers, visitors, surfaces and equipment. Standardized disinfection of protective equipment helps break this chain.
In radiology, fluoroscopy and angiography areas, the same aprons may be used by different staff or patient workflows throughout the day. Sweat, hand contact, glove contact and hanging areas make surface hygiene critical.
Hospital-associated microorganisms such as MRSA, VRE, C. difficile and some gram-negative bacteria can survive on surfaces under suitable conditions. Reusable equipment therefore requires a planned cleaning approach.
Respiratory viruses, norovirus and similar agents can be transferred through contaminated hands or surfaces. An enclosed UVC cabinet offers an additional disinfection step for protective equipment surfaces without chemicals.
The coating, seams and internal protective structure of lead aprons can be affected by frequent and intensive chemical applications. UVC LED technology is a practical alternative that supports the hygiene process without surface contact.
Oley MRT does not replace hand hygiene, surface cleaning, equipment storage rules or institutional infection control procedures. It adds a more standardized and traceable lead apron hygiene step to these practices.
OLEY MRT targets long-lasting and stable UVC performance with thermal management, three-stage filtration, reflective interior surface architecture and constant-current drivers.
Each LED group is supported by custom heatsinks and integrated cooling blocks to reduce optical power loss and extend system life.
Aluminum cooling blocks integrated behind each LED group provide continuous thermal management, reducing optical power loss and degradation.
Constant-current technology operating independently of mains voltage provides resistance to voltage fluctuations and supports operational continuity under demanding conditions.
Door safety, magnetic switch and automatic UVC cut-off architecture create a controlled safety chain that prioritizes user health even while the cycle is active.
The system is active, UVC lights are on and the disinfection cycle is running.
When the door is opened unintentionally or by force, the safety chain is triggered.
The magnetic safety switch activates within milliseconds and stops the system.
Within milliseconds the UVC current is cut off; eye and skin health is protected.
Fan-assisted HEPA filtration: Air inside the cabinet is filtered from particles. High-flow circulation also cools LED chips and maximizes system life.
Maximum hygiene for protective equipment in radiology and ionizing radiation areas
Oley MRT UVC disinfection cabinet is developed for hygienic cleaning of lead aprons, thyroid shields, gonad shields, radiation glasses and similar protective equipment.
Enables frequently used radiation protective equipment in radiology departments to enter a standard UVC disinfection cycle after each use.
Helps regularly clean lead aprons whose hygiene need increases due to sweat, contact and intensive use during long procedures.
Supports contactless disinfection of radiation protective aprons and accessories used between operations inside an enclosed cabinet.
Provides fast, chemical-free and controlled hygiene for protective aprons used in panoramic X-ray and dental imaging units.
Creates a regular, traceable and fast disinfection point for surface hygiene of lead glasses, thyroid shields, gonad shields and similar accessories.
Helps hygienically prepare protective equipment used by industrial teams working with ionizing radiation after shifts and field use.
You can download the specification file prepared for the technical features of the lead apron disinfection cabinet, radiation protective equipment UVC disinfection system and hospital hygiene equipment from this section.
The OLEY MRT technical specification includes the technical criteria needed for 275 nm UVC LED technology, hanging lead apron disinfection, HEPA and activated carbon filtration, safe enclosed cabinet architecture, cycle time and radiology equipment hygiene.
A UV disinfection cabinet is an enclosed disinfection system that uses UVC rays to inactivate bacteria, viruses and microorganisms. Oley MRT is developed especially for lead apron and ionizing radiation protective equipment hygiene.
A UV disinfection cabinet uses 275 nm UVC LED technology to damage the DNA structure of microorganisms and inactivate them. Homogeneous light distribution inside the cabinet provides effective disinfection on all surfaces.
A UV disinfection cabinet is used for hygiene of protective equipment in radiology centers, angiography and fluoroscopy areas, operating rooms, dental radiology units and industrial radiation applications.
Yes, a UV disinfection cabinet can be used specifically for lead apron disinfection. UVC rays provide hygiene without damaging the apron structure and support safe use of radiology equipment.
A PPE disinfection cabinet is a UV cabinet system that disinfects personal protective equipment. For Oley MRT, this means lead aprons, thyroid shields, gonad shields, radiation glasses and similar radiation protective products.
A UV disinfection cabinet generally provides effective disinfection within 10-15 minutes. This fast cycle supports uninterrupted hygiene in high-use areas.
Yes, UV cabinet systems provide user safety because they operate in an enclosed structure. Door safety sensors and automatic shut-off systems prevent UV light from escaping.
UV disinfection cabinets with advanced UVC LED technology do not produce ozone. This provides safe disinfection without harming human health.
With the Oley MRT UVC cabinet, lead aprons, thyroid shields, gonad shields, radiation glasses and suitable protective accessories used in radiology units can be disinfected.
A UV disinfection cabinet targets up to 99.99% inactivation of bacteria and viruses when used correctly. It is therefore preferred as a strong support solution that reduces chemical use in radiology equipment hygiene.
A radiology equipment disinfection cabinet is preferred because it provides fast, chemical-free and safe disinfection for lead aprons and radiation protective equipment. It helps reduce cross-contamination risk and improves equipment hygiene standards.
UV disinfection cabinet prices vary according to capacity, LED power, filtration system, hanging architecture and technology used. Models positioned for lead apron and radiation protective equipment use offer higher performance.
A UV cabinet system provides disinfection without chemicals. This makes it environmentally friendly and helps prevent equipment damage. It is also a faster and lower-cost solution.
Yes, the Oley MRT UVC cabinet can be positioned for compact placement needs. It provides fast protective equipment disinfection with high efficiency in radiology and fluoroscopy areas.
Let us prepare the right cabinet positioning, technical specification text and proposal according to your radiology, fluoroscopy, angiography or industrial radiation use case.